HPE ProLiant DL385 Gen10 Plus v2 Parts

2U rack serverAMD EPYC 7003 processors

The HPE ProLiant DL385 Gen10 Plus v2 is a 2U rack server for one or two AMD EPYC 7003 processors and DDR4-3200 memory, and its processor kits come without cooling: above 155W add the High Performance heat sink and Max Performance fan kit, at 155W or less the standard ones. This page lists the 259 parts HPE's QuickSpecs have listed for it across editions, by part type.

  • 259 HPE-listed parts
  • 32 DIMM slots, up to 8TB
  • Up to 36 SFF, 20 LFF or 32 NVMe drives
  • Up to 8 PCIe 4.0 slots on 3 risers
  • Flex Slot power, 500W to 1600W output

Specifications: HPE QuickSpecs a50002560enw, version 30 (July 28, 2025), which HPE has retired. Memory and drive figures match the DL385 Gen10 Plus v2 Memory and Drives pages.

Shop DL385 Gen10 Plus v2 parts by type

More DL385 Gen10 Plus v2 parts: chassis, expansion and enablement

Most ordered from this list

The parts on this page our customers order most, for any server.

  1. DrivesP28352-B212.4TB SAS 12G Mission Critical 10K SFF BC 512e Multi Vendor HDD
  2. Drives861686-B211TB SATA 6G Business Critical 7.2K LFF LP Multi Vendor HDD
  3. DrivesP28586-B211.2TB SAS 12G Mission Critical 10K SFF BC Multi Vendor HDD
  4. DrivesP47808-B21960GB SATA 6G Read Intensive LFF LPC Multi Vendor SSD
  5. Drives881787-B2112TB SATA 6G Business Critical 7.2K LFF LP Helium 512e Multi Vendor HDD
  6. Power supplies865434-B21800W Flex Slot -48VDC Hot Plug Low Halogen Power Supply Kit
  7. Drives861683-B214TB SATA 6G Business Critical 7.2K LFF LP Multi Vendor HDD
  8. DrivesP40500-B213.84TB SATA 6G Read Intensive SFF BC Multi Vendor SSD
  9. DrivesP40505-B213.84TB SATA 6G Mixed Use SFF BC Multi Vendor SSD
  10. Drives833928-B214TB SAS 12G Business Critical 7.2K LFF LP Multi Vendor HDD

DL385 Gen10 Plus v2 at a glance

Processors

One or two AMD EPYC processors of the same model: 7003-series (model numbers 7xx3), or the 7002-series 7252, 7302 or 7402.

Processor kits include no heat sink or fans: above 155W, the High Performance Heat Sink Kit (P14610-B21) and the Max Performance Fan Kit (P14608-B21); at 155W or less, the Standard Heat Sink Kit (P39994-B21) and the Standard Fan Kit (P37042-B21).

The 7xx3X models also need DIMM blanks and do not support a mid-tray cage. With the 4LFF mid-tray cage, HPE limits processors to 225W (turbo to 240W). DL385 Gen10 Plus v2 Processors

Memory

32 DIMM slots, 16 per processor on 8 channels; all 32 need two processors. DDR4-3200 kits: RDIMMs of 8GB to 64GB, a 128GB LRDIMM and a 256GB 3DS LRDIMM; the three types do not mix, nor do x4 and x8 kits. Up to 8TB with 256GB LRDIMMs in all 32 slots, 2TB with 64GB RDIMMs; 4TB per processor.

HPE allows the 256GB LRDIMM in three builds only, at 25°C ambient: 8LFF, and 8SFF or 16SFF with SAS or SATA drives. 128GB and 256GB LRDIMMs do not go in an SFF chassis with a mid-tray cage.

With two DIMMs per channel the 8GB to 128GB kits keep 3200 MT/s and the 256GB runs at 2933 MT/s. A mid-tray cage with a processor of 155W or more needs the DIMM blank kit (P07818-B21). DL385 Gen10 Plus v2 Memory

Drives

Up to 36 SFF drives (24 front, 8 mid-tray, 4 rear) or 20 LFF drives (12 front, 4 mid-tray, 4 rear), on the Basic Carrier (BC) and Low Profile (LP) carriers; the 4LFF rear cage uses the primary and secondary riser space.

Up to 24 NVMe drives in front of the 8SFF model, 32 with an 8SFF mid-tray cage; NVMe cages need a tri-mode controller or an NVMe bundle kit, U.3 and U.2 cages do not mix, and rear NVMe drives must be 10W or less.

Rear drives, 12 or more LFF drives and the mid-tray cages need the Max Performance fan kit. SATA M.2 SSDs on a PCIe M.2 kit, not with a mid-tray cage or the NS204i-p. DL385 Gen10 Plus v2 Drives

Storage controllers

The embedded SATA controller runs in AHCI mode by default; SR100i software RAID covers up to 2 U.3 NVMe SSDs, in UEFI mode only, on the 8SFF and 8LFF models.

Smart Array E208i-a, E208i-p and E208e-p, and P408i-a, P408i-p, P408e-p and P816i-a; tri-mode MR216i, MR416i, SR416i-a and SR932i-p controllers for NVMe as well as SAS and SATA. Performance RAID controllers need the HPE Smart Storage Battery (P01366-B21).

The NS204i-p boot device fits slot 1 of the primary riser only. DL385 Gen10 Plus v2 Controllers

Networking

No embedded network ports: an OCP 3.0 slot at the rear, PCIe adapters and a dedicated 1Gb iLO port. DL385 Gen10 Plus v2 Adapters

Expansion

Up to 8 PCIe 4.0 slots with two processors: 3 on the primary riser, 3 on the secondary and 2 on the tertiary riser; the secondary riser needs processor 2, and the tertiary riser's slots run from it. Riser cards

Power

Flex Slot hot-plug power supplies from 500W to 1800W-2200W, including 800W and 1600W -48VDC models; HPE caps the output at 1600W in the Gen10 Plus v2. The 1000W, 1600W and 1800W-2200W supplies need 200VAC to 240VAC. HPE does not support mixing two different power supplies. DL385 Gen10 Plus v2 Power Supplies

Management

HPE iLO 5. Management hardware

Specifications from HPE QuickSpecs a50002560enw, version 30 (July 28, 2025). Memory figures match the DL385 Gen10 Plus v2 Memory page.

Before you order SFF drives, check the drive carrier. The DL385 Gen10 Plus v2 uses Basic Carrier (BC) drive cages, not the Smart Carrier (SC) cages of the DL385 Gen10 Plus, and every SFF drive on this list has BC in its name, such as P28352-B21. LFF drives use the Low Profile (LP) carrier on both servers, so LFF drives such as 881781-B21 fit either. Both servers take the same DDR4-3200 kits, so memory does not tell them apart; a 7xx3 processor (EPYC 7313, 7443, 7763) means a v2, since HPE does not support 7003 processors in the Gen10 Plus. Find the processor model in iLO under System Information › Processors.

Gen10 Plus, Gen10 Plus v2 or Gen11? How to tell

A 7xx3 processor means a Gen10 Plus v2 and a 9xx4 or 9xx5 processor a Gen11. The Gen10 Plus and the v2 share three 7xx2 models and their memory kits, so with a 7xx2 processor the SFF drive cages tell them apart: Smart Carrier on the Gen10 Plus, Basic Carrier on the v2. LFF drives use the Low Profile carrier on both.

What to checkDL385 Gen10 PlusDL385 Gen10 Plus v2 This pageDL385 Gen11
Processor model numbers7xx2: EPYC 7302, 7402, 77027xx3, or 7252, 7302, 7402: EPYC 7313, 7443, 77639xx4 or 9xx5: EPYC 9124, 9354, 9555
MemoryDDR4-3200, 32 slotsDDR4-3200, 32 slotsDDR5-4800 or DDR5-6400, 24 slots
Memory kits look likeP07640-B21, P07646-B21P07640-B21, P07646-B21P50312-B21, P64985-B21
Parts pageDL385 Gen10 Plus partsYou are hereDL385 Gen11 parts

From the HPE QuickSpecs of each server: HPE ProLiant DL385 Gen10 Plus a00073549enw version 31; HPE ProLiant DL385 Gen10 Plus v2 a50002560enw version 30; HPE ProLiant DL385 Gen11 a50004300enw version 49.

All 259 DL385 Gen10 Plus v2 parts

Grouped by part type; within each group the parts are in the order of HPE's QuickSpecs. Open a group, or type a part number or a few words to filter the whole list.

DL385 Gen10 Plus v2 parts questions

How much memory does the DL385 Gen10 Plus v2 support?

Up to 8TB with two processors: 256GB DDR4-3200 LRDIMMs in all 32 slots, up to 4TB per processor. HPE allows the 256GB LRDIMM in three builds only, at 25°C ambient: 8LFF, and 8SFF or 16SFF with SAS or SATA drives. With 64GB registered DIMMs the maximum is 2TB. All 32 slots need two processors. 128GB and 256GB LRDIMMs do not go in an SFF chassis with a mid-tray cage. With two DIMMs per channel the 8GB to 128GB kits keep 3200 MT/s and the 256GB runs at 2933 MT/s. A mid-tray cage with a processor of 155W or more needs the DIMM blank kit (P07818-B21).

Which drives fit the DL385 Gen10 Plus v2?

2.5-inch SFF drives on HPE's Basic Carrier (BC) in SAS, SATA or U.3 NVMe; 3.5-inch LFF drives on the Low Profile (LP) carrier in SAS or SATA, plus LFF LPC SSDs; and SATA M.2 SSDs on HPE's M.2 enablement kit. The controller and the drive cage decide which interfaces work.

How do I tell which processors my DL385 Gen10 Plus v2 has?

Read the processor model in iLO under System Information › Processors. HPE lists EPYC 7003 processors for the v2, whose model numbers have 3 as the last digit, such as the 7313, 7443 or 7763 (and the F and X models such as the 75F3 and 7773X), plus the 7252, 7302 and 7402. Two processors must be the same model. Processor kits come without a heat sink or fans: above 155W, order the High Performance Heat Sink Kit (P14610-B21) and the Max Performance Fan Kit (P14608-B21); at 155W or less, the Standard Heat Sink Kit (P39994-B21) and the Standard Fan Kit (P37042-B21).

Is my server a DL385 Gen10 Plus v2, a Gen10 Plus or a Gen11?

Check the processor model number. A 7xx3 processor, such as the 7313, means a Gen10 Plus v2. The Gen11 runs EPYC 9004 or 9005 processors (9xx4 or 9xx5, such as the 9124 or 9555) with DDR5 memory in 24 slots. HPE lists 7xx2 processors for the Gen10 Plus and does not support 7003 processors in it; the v2 also lists the 7252, 7302 and 7402, so with one of those check the SFF drive cages: Basic Carrier (BC) on the v2, Smart Carrier (SC) on the Gen10 Plus. LFF drives use the Low Profile (LP) carrier on both. The Gen10 Plus and the v2 take the same DDR4-3200 kits; processors and SFF drives differ, so buy those from the page for your generation.

Are refurbished parts on this list too?

Yes. A refurbished part carries the same HPE part number as a new one, so it is listed here under that number, and each listing shows its condition. Every part ships tested or factory sealed.

What warranty comes with DL385 Gen10 Plus v2 parts?

A replacement warranty of 1 to 5 years, depending on the part: memory is covered for 5 years, and many other parts for 1 or 3 years.

Other DL385 generations

Ships same dayMost orders ship the same business day
1 to 5 year warrantyTested or factory sealed
Purchase orders acceptedCard, P-card, ACH, wire or PayPal too
Drives82 parts

All drives on the DL385 Gen10 Plus v2 Drives page

Hard Disk Drives - 2.5in SFF SAS

Enterprise - 12G SAS - SFF Drives
SED (Self-Encryption Drive) HDDs
HPE note

Requirements for MR Tri-mode controller SED support TPM is not required for Local Key Management as key is stored in controller iLO Advanced is required for Remote Key Management. Key is stored in remote key manager (Ex. ESKM)

Hard Disk Drives - 3.5in LFF SAS

Midline - 12G SAS - LFF Drives

Hard Disk Drives - 3.5in LFF SATA

Midline - 6G SATA - LFF Drives

Solid State Drives - 2.5in SFF SAS

Read Intensive - 12G SAS - SFF - Solid State Drives
Mixed Use - 12G SAS - SFF - Solid State Drives

Solid State Drives - 2.5in SFF SATA

Mixed Use - 6G SATA - SFF - Solid State Drives
Read Intensive - 6G SATA - SFF - Solid State Drives
SED (Self-Encryption Drive) SSDs
HPE notes (2)
  • Requirements for Direct Attach SED support TPM2.0 is required for Local Key Management. Keys will be locally encrypted and stored by TPM iLO Advanced is required for Remote Key Management. Key is stored in remote key manager (Ex. ESKM)
  • Requirements for MR Tri-mode controller SED support TPM is not required for Local Key Management as key is stored in controller iLO Advanced is required for Remote Key Management. Key is stored in remote key manager (Ex. ESKM)

Solid State Drives - 3.5in LFF SAS

Mixed Use SAS – LFF- Solid State Drives

Solid State Drives - 3.5in LFF SATA

Read Intensive – 6G SATA - LFF – Solid State Drives

Solid State Drives - SATA M.2

Internal Dual M.2 Kit
  • 878783-B21 HPE Universal SATA 6G AIC HHHL M.2 SSD Enablement Kit
    HPE note

    SATA M.2 cannot be supported in LFF/SFF chassis with mid tray configuration due to thermal concern In 24SFF/12LFF/8LFF chassis, only slot 1 can support it and under ambient temperature of 30C. If the Max CPU power is lower than 240W, the supported ambient temp. is 30C If the Max CPU power is higher than 240W, the supported ambient temp. is 25C This kit requires a PCIe slot and supports up to two M.2 SSDs which should be the same SSD SKUs

Read Intensive - M.2 - Solid State Drives

Solid State Drives - 2.5in SFF NVMe

Read Intensive - NVMe - SFF - Solid State Drives
Mixed Use - NVMe - SFF - Solid State Drives
  • P70426-B21 HPE 3.2TB NVMe Gen4 High Performance Mixed Use SFF BC U.3 PS1030 SSD
  • P70428-B21 HPE 6.4TB NVMe Gen4 High Performance Mixed Use SFF BC U.3 PS1030 SSD

Hard Drive Blank Kits

Memory9 parts
Network adapters48 parts

All network adapters on the DL385 Gen10 Plus v2 Adapters page

HPE Networking

1 Gigabit Ethernet adapters
10 Gigabit Ethernet adapters
10/25 Gigabit Ethernet adapters
100/200/400 Gigabit Ethernet adapters
HPE notes (2)
  • 4-port adapters go only into Slot 1.
  • A minimum of two Gigabytes (2 GB) of server memory is required per each adapter.
OCP Adapters
HPE notes (3)
  • OCP adapters do not consume PCIe slot.
  • Only 1 slot is available for OCP adapters.
  • Only SFF OCP adapters below 35W can be supported
HPE InfiniBand
Pensando Distributed Services Card (DSC)
  • P26966-B21 Pensando Distributed Services Platform DSC-25 Enterprise 10/25Gb 2-port SFP28 Card
    HPE note

    Each card instance requires one RTU license of Silver or Platinum software. In case of more than one adapter, RTU licenses doesn’t need to be of the same part number.

HPE PCIe Workload Accelerator Options
Storage controllers17 parts

All storage controllers on the DL385 Gen10 Plus v2 Controllers page

HPE note

All performance RAID controllers are supported by the HPE Smart Storage Battery (P01366-B21), which supports multiple devices and is sold separately.

Essential RAID Controllers
Tri-mode RAID Controllers
HPE notes (3)
  • When selecting SR RAID controllers for external storage (E208e, 804398-B21) and MR RAID controllers for internal storage(MR216i/MR416i) in the order, please be aware these two products use different RAID configuration tools. HPSSA (HP SR Storage Administrator) is only supported on SR (SmartRAID) controllers. MR (MegaRAID) controllers will support a different tool named MR Storage Administrator
  • Not supporting mixing of MR (MegaRAID) series internal controllers and SR (SmartRAID) series internal controllers
  • MR (MegaRAID) series controllers are not supported with Intelligent Provisioning feature
NVMe Adapters
Drive cages and backplanes17 parts
  • P14503-B21 HPE DL38X Gen10 Plus 4LFF SAS/SATA Low Profile Mid Tray Drive Cage Kit
    HPE note

    Supported with both the 8 and 12 LFF model. With this mid-tray only single-wide (8.5-inch cards with connections or less) cards are supported. Full Length PCIe cards cannot be supported. This requires Max Performance Fan kit (P14608-B21). Requires DIMM Blank kit (P07818-B21), if this option is selected with processor 155W and above. This mid tray drive cage kit contains 1U high performance heat sink(s). Please note this is not the same heat sink as included in the High Performance Heat Sink Kit (P14610-B21)

  • P55517-B21 HPE ProLiant DL385 Gen10 Plus v2 4LFF SAS/SATA LP Drive Cage Kit
    HPE note

    Supported with both the 8 and 12 LFF model. With this mid-tray only single-wide (8.5-inch cards with connections or less) cards are supported. Full Length PCIe cards cannot be supported. This requires Max Performance Fan kit (P14608-B21). Requires DIMM Blank kit (P07818-B21), if this option is selected with processor 155W and above. This mid tray drive cage kit contains 1U high performance heat sink(s). Please note this is not the same heat sink as included in the High Performance Heat Sink Kit (P14610-B21) When this Mid Tray is selected with 8LFF CTO Server and no other controllers selected then 2P must be selected.

  • P39600-B21 HPE ProLiant DL385 Gen10 Plus v2 8SFF x1 U.3 BC Mid Tray Basic Drive Cage Kit
    HPE note

    Supported with both the 8 and 24 SFF model. With this mid-tray only single-wide (8.5-inch cards with connections or less) cards are supported. Full Length PCIe cards cannot be supported. This requires Max Performance Fan kit (P14608-B21). Requires DIMM Blank kit (P07818-B21), if this option is selected with processor 155W and above. This mid tray drive cage kit contains 1U high performance heat sink(s). Please note this is not the same heat sink as included in the High Performance Heat Sink Kit (P14610-B21)

  • P38847-B21 HPE ProLiant DL385 Gen10 Plus v2 8SFF x4 U.3 BC Mid Tray Premium Drive Cage Kit
    HPE note

    Supported with both the 8 and 24 SFF model. With this mid-tray only single-wide (8.5-inch cards with connections or less) cards are supported. Full Length PCIe cards cannot be supported. This requires Max Performance Fan kit (P14608-B21). Requires DIMM Blank kit (P07818-B21), if this option is selected with processor 155W and above. This mid tray drive cage kit contains 1U high performance heat sink(s). Please note this is not the same heat sink as included in the High Performance Heat Sink Kit (P14610-B21)

  • P14579-B21 HPE ProLiant DL38X Gen10 Plus 2LFF Primary Riser Cage Kit
    HPE note

    Supported only on 8 LFF & 12 LFF models. This option occupies primary riser slot. When P14579-B21 and P14580-B21 are selected. Double-wide GPUs cannot be selected When P14579-B21 is selected, maximum 1x double-wide GPU can be supported When P14579-B21 is selected, HPE DL38X Gen10+ Slot1 x16 Slot2/3 Kit (P14600-B21) CANNOT be selected

  • P55518-B21 HPE ProLiant DL38x Gen10 Plus 2LFF UBM to Tri-Mode LP Primary Riser Backplane Kit
    HPE note

    Supported only on 8 LFF & 12 LFF models. This option occupies primary riser slot. This 2LFF Drive cage needs support of trimode controllers from the following list: HPE MR416i-p Gen10+ Controller HPE MR416i-a Gen10+ Controller HPE MR216i-p Gen10+ Controller HPE MR216i-a Gen10+ Controller When this is selected. Double-wide GPUs cannot be selected When this is selected, maximum 1x double-wide GPU can be supported When this is selected, HPE DL38X Gen10+ Slot1 x16 Slot2/3 Kit (P14600-B21) CANNOT be selected

  • P14580-B21 HPE ProLiant DL38X Gen10 Plus 2LFF Tertiary Riser Cage Kit
    HPE note

    Supported only on 8 LFF & 12 LFF Models. This option occupies secondary and tertiary riser slots. When P14579-B21 and P14580-B21 are selected. Double-wide GPUs cannot be selected When P14580-B21 is selected, maximum 1x double-wide GPU can be supported This option (P14580-B21) CAN NOT be selected when HPE DL38X Gen10+ Slot1 x16 Slot2/3 Kit (P14600-B21) Qty is 2

  • P55519-B21 HPE ProLiant DL38x Gen10 Plus 2LFF UBM to Tri-Mode LP Tertiary Riser Backplane Kit
    HPE note

    Supported only on 8 LFF & 12 LFF Models. This option occupies secondary and tertiary riser slots. This 2LFF Drive cage needs support of trimode controllers from the following list: HPE MR416i-p Gen10+ Controller HPE MR416i-a Gen10+ Controller HPE MR216i-p Gen10+ Controller HPE MR216i-a Gen10+ Controller When this is selected. Double-wide GPUs cannot be selected When this is selected, maximum 1x double-wide GPU can be supported This option CANNOT be selected when HPE DL38X Gen10+ Slot1 x16 Slot2/3 Kit (P14600-B21) Qty is 2

  • P26922-B21 HPE ProLiant DL38X Gen10 Plus 2SFF x4 Tri-Mode 24G U.3 BC Front/Tertiary Drive Cage Kit
    HPE note

    This option can be used with all CTO Servers. Max Qty=2, allowed on 8 SFF model; Max Qty=1, allowed on 8 LFF, 12 LFF and 24 SFF models. Only 1 drive cage can be ordered with 12 LFF and 24 SFF models. 8SFF Model with 2 drive cages, requires Universal Media Bay. When Qty=2, HPE DL38X Gen10+ MiniSAS 3POS Cbl (P14605-B21) must be selected. When supported in front, only SATA/NVMe. When supported in rear, can support SAS/SATA/NVMe. When supported in rear with NVMe. Only 1 NVMe drive can be supported and must be lower or equal to 10W. When this drive cage is installed in rear and P26924-B21 in front within an 8LFF CTO server, and no tri- mode controller or NVMe bundle kits are ordered, max=3 NVMe drives can be supported as direct attach When this drive cage is installed in rear and another P26922-B21 in front with Universal Media Bay within an 8SFF CTO server, and no tri-mode controller or NVMe bundle kits are ordered, max=3 NVMe drives can be supported as direct attach

  • P35418-B21 HPE ProLiant DL385 Gen10 Plus v2 2SFF 4x U.3 Premium Secondary Riser Kit
    HPE note

    This 2SFF drive cage kit can support either NVMe, SAS or SATA type of drives in front or rear. This drive cage occupies Secondary slot therefore no other secondary riser can be selected. Double-wide GPU cannot be installed on this riser. When this option is selected, Tertiary riser cannot be selected. When supported with NVMe. Only 1 NVMe drive can be supported and must be lower or equal to 10W. When this drive cage is installed in rear and P26924-B21 in front within an 8LFF CTO server, and no tri- mode controller or NVMe bundle kits are ordered, max=3 NVMe drives can be supported as direct attach When this drive cage is installed in rear and P26922-B21 in front with Universal Media Bay within an 8SFF CTO server, and no tri-mode controller or NVMe bundle kits are ordered, max=3 NVMe drives can be supported as direct attach

  • P26924-B21 HPE ProLiant DL300 Gen10 Plus 2U 2SFF x4 Tri-Mode 24G U.3 BC Side-by-Side Drive Cage Kit
    HPE note

    This 2SFF drive cage kit can only support either NVMe or SATA type of drives in front. No SAS drives can be supported This option can be only be used with 8 LFF model. Only SATA/NVMe drives can be supported. When this drive cage is installed and with a P26922-B21 in rear within an 8LFF CTO server, and no tri- mode controller or NVMe bundle kits are ordered, max=3 NVMe drives can be supported as direct attach

  • P26930-B21 HPE ProLiant DL300 Gen10 Plus 2U 8SFF SAS/SATA 12G BC Front Bay 1/2 Drive Cage Kit
    HPE note

    Supported only on 8 SFF Model. Maximum up to 2 drive cages can be selected. The 24 SFF chassis doesn’t need to select this drive cage kit since the chassis already includes 3x 8SFF SAS/SATA drive cages.

  • P55516-B21 HPE ProLiant DL38x Gen10 Plus 8SFF SAS/SATA to Tri-Mode Controller Backplane Kit
    HPE note

    Supported only on 8 SFF Model. Maximum up to 2 drive cages can be selected. This 8SFF SAS/SATA Drive cage needs trimode support from the following list of controllers: o HPE MR416i-p Gen10+ Controller o HPE MR416i-a Gen10+ Controller o HPE MR216i-p Gen10+ Controller o HPE MR216i-a Gen10+ Controlle

  • P26931-B21 HPE ProLiant DL300 Gen10 Plus 2U 8SFF x4 Tri-Mode 24G U.3 BC Front Drive Cage Kit
    HPE note

    Supported only on 8 SFF Model. Maximum up to 3 drive cages can be selected. When this drive cage is selected, NVMe Bundle Kit (Min=1, Max=1) or Tri-mode controller must be selected. When 8 SFF NVMe U.3 or U.2 drive cages is selected instead of SAS/SATA drive cages, HPE DL38X Gen10 8 SFF Front Cage Removal FIO Option (873763-B21) must be selected.

  • P27194-B21 HPE ProLiant DL300 Gen10 Plus 2U 8SFF x1 Tri-Mode 24G U.3 BC Front Drive Cage Kit
    HPE note

    Supported only on 8 SFF Model. SAS/SATA controllers or Embedded controller (SR100i) cannot support this drive cage. Only Tri-mode controllers can support it. When 8 SFF NVMe U.3 or U.2 drive cages is selected instead of SAS/SATA drive cages, HPE DL38X Gen10 8 SFF Front Cage Removal FIO Option (873763-B21) must be selected.

  • P26932-B21 HPE ProLiant DL300 Gen10 Plus 2U 8SFF x4 NVMe 16G U.2 BC Front Drive Cage Kit
    HPE note

    Supported only on 8 SFF Model. Maximum up to 3 drive cages can be selected. When this drive cage is selected, NVMe Bundle Kit (Min=1, Max=1) or Tri-mode controller must be selected. SAS/SATA controllers or Embedded controller (SR100i) cannot support this drive cage. Only Tri-mode controllers can support it. When 8 SFF NVMe U.3 or U.2 drive cages is selected instead of SAS/SATA drive cages, HPE DL38X Gen10 8 SFF Front Cage Removal FIO Option (873763-B21) must be selected.

Media Bay Kits
  • P14609-B21 HPE DL38X Gen10 Plus Universal Media Bay Kit
    HPE note

    The HPE DL385 Gen10 Plus Universal Media bay provides front Display Port and 2xUSB 2.0; plus support for 2x SFF front drives or 2 NVMe front drives and ODD support (Not included); and can only be located in Box1 in either an 8 SFF or 8+8 SFF model. This is an 8SFF model option only. This option cannot be ordered when HPE 8SFF Front Remove SPEC Perf FIO (873763-B21) is NOT selected, and Qty=2 of following options are selected : HPE DL300 Gen10 Plus 8SFF SAS/SATA Basic Carrier Drive Cage Kit (P26930-B21), HPE DL300 Gen10 Plus 8SFF NVMe U.3 Premium Basic Carrier Drive Cage Kit (P26931-B21), HPE DL300 Gen10 Plus 8SFF NVMe U.3 Basic Carrier Drive Cage Kit (P27194-B21), HPE DL300 Gen10 Plus 8SFF NVMe U.2 Premium Basic Carrier Drive Cage Kit (P26932- B21) When HPE Universal SATA 6G AIC HHHL M.2 SSD Enablement Kit (878783-B21) is selected as well, no optical drive device can be supported.

Riser cards10 parts
  • P14575-B21 HPE DL38X Gen10 Plus Primary NEBS-compliant Riser Kit
    HPE note

    This riser kit contains a primary riser PCA with 3 slots for x8/x16/x8 When this kit is selected and if customer wants to select Sec or Ter Riser then the risers must be NEBS Risers only (P14575-B21 OR P14577-B21) Max =2 of this kit can be selected A Max Qty=1 Doublewide GPU per riser. The top x16 PCIe slot connector on this riser kit CANNOT be utilized as the Doublewide GPU occupies this space When HPE DL38X Gen10+ Prim NEBS Riser Kit (P14575-B21) is Qty =2, HPE DL38X Gen10+ Tertiary NEBS Riser Kit (P14577-B21) CANNOT be selected When P14575-B21 is Qty=1 then it must be installed in Primary. When P14575-B21 is Qty =2 then 2nd processor must be selected When this kit is selected, A100 GPU card cannot be supported

  • P14577-B21 HPE DL38X Gen10 Plus Tertiary NEBS-compliant Riser Kit
    HPE note

    This riser kit contains a secondary riser PCA with 3 slots for x8/x16/x8 and a tertiary riser PCA with 1 slot for x16 Requires the selection of a 2nd processor When this kit is selected and if customer wants to select Sec or Ter Riser then the risers must be NEBS Risers only (P14575-B21 OR P14577-B21) When HPE DL38X Gen10+ Prim NEBS Riser Kit (P14575-B21) is Qty =2, HPE DL38X Gen10+ Tertiary NEBS Riser Kit (P14577-B21) CANNOT be selected Max Qty=2 Doublewide GPU per riser kit Max Qty=4 Singlewide/ Half Length GPU per riser kit When HPE DL38X Gen10+ Tertiary NEBS Riser Kit (P14577-B21) is selected HPE DL38X Gen10+ Prim NEBS Riser Kit (P14575-B21) MUST BE selected When this kit is selected, A100 GPU card cannot be supported

  • P14587-B21 HPE DL38X Gen10 Plus x8/x16/x8 Secondary Riser Kit
    HPE note

    Requires selection of a 2nd processor Slot 1, 2, 3 Secondary location Supports Full Height and Full length cards on slot 1, 2 only Bus width x8, x16, x8 Connector Width x16, x16, x16

  • P14589-B21 HPE DL38X Gen10 Plus x16/x16 Slot 1/2 Secondary Riser Kit
    HPE note

    Requires selection of a 2nd processor Slot 1 or 2 Secondary location Supports Full Height and Full length cards. Bus width x16, x16 Connector Width x16, x16

  • P14590-B21 HPE DL38X Gen10 Plus x16/x16 Slot 2/3 Secondary Riser Kit
    HPE note

    Requires selection of a 2nd processor Slot 2 or 3 in Secondary location Supports Full Height and Full length cards on slot 2 only Bus width x16, x16, Connector Width x16, x16

  • P14581-B21 HPE DL38X Gen10 Plus x8/x8 Tertiary Riser Kit
    HPE note

    Supports Full Height, Full-length cards and Full Height, Half- length cards. Bus width x8, x8, Connector Width x16, x16.

  • P14588-B21 HPE DL38X Gen10 Plus x16 Tertiary Riser Kit
    HPE note

    Requires selection of a 2nd processor Slot 1 in Tertiary location Supports Full Height and Full length cards Bus width x16, Connector Width x16

  • P14600-B21 HPE DL38X Gen10 Plus Slot1 x16 Adder for Slot2/3 Riser Kit
    HPE note

    This is required to add additional x16 PCIe Gen4 lanes for Primary/Secondary Risers (P14599-B21) or (P14590-B21)

  • P38771-B21 HPE DL385 Gen10 Plus Primary/Secondary Riser Cage without Retainer Clip
    HPE note

    This is required when an A100 GPU card is supported Max =2 of this kit can be selected If Q’ty =2 of this kit is selected then a secondary riser must be selected

  • P38774-B21 HPE DL385 Gen10 Plus Tertiary Riser Cage without Retainer Clip
    HPE note

    This is required when an A100 GPU card is supported Max =1 of this kit can be selected This option requires selection of a Tertiary Riser

Power supplies10 parts

All power supplies on the DL385 Gen10 Plus v2 Power Supplies page

HPE Power Supplies

HPE notes (3)
  • All power supplies in a server should match. Mixing Power Supplies is not supported.
  • Option kits contain the specified power supply and a PDU IEC cable.
  • 1000W, 1600W and 2200W power supplies only support high line voltage.
Processors23 parts

All processors on the DL385 Gen10 Plus v2 Processors page

HPE Processors

Processor Option Kits
HPE notes (5)
  • Mixing of 2 different processor models are NOT allowed.
  • DDR4 memory speed will depend on the quantity and type of DIMMs installed.
  • Processors greater than 155W will require the High Performance Heat Sink.
  • Processors greater than 155W will require the Max Performance Fan Kit.
  • Processor kits don’t include heat sink and fans.

Heat Sinks

Cable kits14 parts
  • P39100-B21 HPE ProLiant DL300 Gen10 Plus GPU 2x 8-pin Cable Kit
    HPE note

    This Cable Kit is for use with the AMD InstinctTM MI100 Accelerator

  • P39102-B21 HPE ProLiant DL300 Gen10 Plus GPU 8-pin Keyed Cable Kit
    HPE note

    This Cable Kit is for use with the NVIDIA A16 64GB, A30 24GB and A40 48GB Computational Accelerator

  • P22829-B21 HPE DL38X Gen10 Plus 8NVMe CPU1/2 Cable Kit
    HPE note

    Maximum q’ty =1 This cable kit can be selected only with respective NVMe bundle SKUs. Refer to NVMe bundle SKU section above in this document

  • P22834-B21 HPE DL38X Gen10 Plus 8NVMe CPU1 Cable Kit
    HPE note

    Maximum q’ty =1 This cable kit can be selected only with respective NVMe bundle SKUs. Refer to NVMe bundle SKU section above in this document

  • P22835-B21 HPE DL38X Gen10 Plus 16NVMe CPU1/2 Cable Kit
    HPE note

    Maximum q’ty =1 This cable kit can be selected only with respective NVMe bundle SKUs. Refer to NVMe bundle SKU section above in this document

  • P14605-B21 HPE DL38X Gen10 Plus Mini SAS 3 Position Cable
    HPE note

    Maximum q’ty =1 This cable kit MUST be selected when HPE DL38X Gen10+ 2SFF x4Tri-Mode U.3 Kit (P26922-B21) is Qty=2

  • P25602-B21 HPE DL385 Gen10 Plus Retimer Card Primary Cable Kit
    HPE note

    This cable kit can be selected only with respective NVMe bundle SKUs. Refer to NVMe bundle SKU section above in this document

  • P25604-B21 HPE DL385 Gen10 Plus Retimer Card Secondary Cable Kit
    HPE note

    This cable kit can be selected only with respective NVMe bundle SKUs. Refer to NVMe bundle SKU section above in this document

  • P36203-B21 HPE ProLiant DL300 Gen10 Plus 2U x2 Tri-Mode Cable Kit
    HPE note

    This cable is to support NVMe U.3/U.2 drive cages with a tri-mode controller, when NVMe configuration is not being built with NVMe bundle SKUs/NVMe direct attach. Refer to OCA for detailed rules.

  • P36202-B21 HPE ProLiant DL300 Gen10 Plus 2U x4 Tri-Mode Cable Kit
    HPE note

    This cable is to support NVMe U.3/U.2 drive cages with a tri-mode controller, when NVMe configuration is not being built with NVMe bundle SKUs/NVMe direct attach. Refer to OCA for detailed rules.

  • P55467-B21 HPE ProLiant DL38x 8SFF SAS/SATA Tri-Mode Cable Kit
    HPE note

    This cable kit can be supported only with 8SFF or 24SFF CTO Server For 8SFF Model, maximum q’ty =1 For 24SFF Model, maximum q’ty =3 This cable kit currently does not work with 8LFF or 12LFF CTO models

  • P58900-B21 HPE ProLiant DL38x LFF SAS/SATA Tri-Mode Cable Kit
    HPE note

    This cable kit can be supported only with 8LFF or 12LFF CTO Server Maximum q’ty =1

  • P55471-B21 HPE ProLiant DL38x Gen10 Plus 2SFF Rear Tri-Mode Cable Kit
  • P55860-B21 HPE ProLiant DL38x Gen10 Plus 4LFF SAS/SATA Tri-Mode Cable Kit
    HPE note

    This cable kit can be used only with 12LFF CTO Server

Fibre Channel HBAs11 parts
Boot devices2 parts
  • P12965-B21 HPE NS204i-p x2 Lanes NVMe PCIe3 x8 OS Boot Device
    HPE note

    NS204i-p will only be supported in Slot 1 of the primary riser and/or Slot 8 of the tertiary riser NS204i-p and Primary Riser HPE DL38X Gen10+ 2x16 Slot 2/3 FIO Kit (P14599-B21) are selected then HPE DL38X Gen10+ Slot1 x16 Slot2/3 Kit (P14600-B21) also must be in the configuration. Legacy Mode setting (758959-B21) and NS204i-p cannot be selected together. HPE Universal SATA AIC HHHL M.2 SSD Kit (878783-B21) and NS204i-p cannot be selected together. When NS204i-p and doublewide GPU are selected together Secondary Riser MUST be selected and doublewide GPU can be maximum of 2.

  • P21868-B21 HPE 32GB microSD RAID 1 USB Boot Drive
    HPE note

    In vSphere 7.0, VMware made changes that impact the use of an SD Card/USB media as a standalone boot device and will be removing support for them after version 7.x. SD Card/USB media can still be used as a standalone boot option through all 7.x releases via published Customer Advisory Usage of SD Card/USB Devices As Standalone Boot Devices Has Changed Due to System Storage Changes For VMware ESXi 7.0 (Or Later). For any major release beyond VMware ESXi 7.x, VMware will require M.2 or another local persistent device as the standalone boot option.

Optical drives3 parts

HPE Optical Drives

Security4 parts
Rack options3 parts
HPE note

CTO Models do not ship with rail kits, they need to be ordered separately

  • P22018-B21 HPE DL38X Gen10 Plus 2U SFF Easy Install Rail Kit
    HPE note

    Supported on SFF Model only

  • P22019-B21 HPE DL38X Gen10 Plus 2U LFF Easy Install Rail Kit
    HPE note

    Supported on LFF Model only

  • P22020-B21 HPE DL38X Gen10 Plus 2U Cable Management Arm for Rail Kit
Management hardware2 parts
  • P14611-B21 HPE DL38X Gen10 Plus System Insight Display Kit
  • P14606-B21 HPE DL38X Gen10 Plus Rear Serial Cable Kit
Fan kits2 parts
  • P37042-B21 HPE ProLiant DL300 Gen10 Plus 2U Standard Fan Kit
    HPE note

    The Standard Fan Kit and the Maximum Performance Fan Kit cannot be selected together CPUs with lower than and equal to 155W, need to select this kit

  • P14608-B21 HPE DL38X Gen10 Plus Maximum Performance Fan Kit
    HPE note

    This kit is required for specific Ambient temperature environments,. Max Performance fan kit consists of 6 fans, these will need to replace all the standard fans in the unit, and fill all 6 fan cages. The 12 LFF and 24 SFF models (including field upgrades to 24 SFF) will already include 6 Max Performance fan kits. The High Performance fan kit is needed to support GPU configurations; or ASHRAE operating environments.

GPUs2 parts

HPE Computation and Graphics Accelerator

  • R9H23C NVIDIA A2 16GB PCIe Non-CEC Accelerator for HPE
    HPE note

    Requires selection of the Max Performance Fan Kit (P14608-B21). Requires selection of the High Performance Heat sink (P14610-B21). This option CANNOT be selected with following Mid Trays: HPE DL38X Gen10+ 4LFF SAS/SATA LP Kit (P14503) HPE DL385 G10+ v2 8SFF x4 U.3 BC Kit (P38847-B21) HPE DL385 G10+ v2 8SFF x1 U.3 BC Kit (P39600-B21) HPE DL38X G10+ 4LFF MID UBM2toTrimod Kit (P55517-B21) This GPU CANNOT be selected with 12LFF CTO Server Certain thermal restrictions will occur when this GPU is selected with SAS4 or NVMe drives on 8SFF or 24SFF CTO Server. Please consult with your HPE reps for more details.

  • R8T26C NVIDIA A16 64GB PCIe Non-CEC Accelerator for HPE
    HPE note

    Requires selection of the Max Performance Fan Kit (P14608-B21). Requires selection of the High Performance Heat sink (P14610-B21). This GPU requires Power Cable Kit (P39102-B21) to be also selected. One Power Cable Kit can support multiple (Max=3) GPUs Double wide GPUs cannot be installed in the same riser where P14600-B21 is installed. Because the double wide GPU heat sink will extend to the P14600-B21 slot. When HPE Universal SATA AIC HHHL M.2 SSD Kit (878783-B21) is selected and since it can only be installed on a primary riser, a secondary riser must be selected to support a DW GPU. This x16 GPU can only installed in x16 electrical slot

Ships same dayMost orders ship the same business day
1 to 5 year warrantyReplacement coverage on every part
5,000+ five-star reviewsShopper Approved, BBB A+ rating
Ships to 120+ countriesBy UPS; duties are collected by the carrier

Building out several servers, or need a part not listed?

Send the part numbers and quantities for each server and we reply to every quote request within 24 hours. Live chat is the fastest way to reach us.