HPE ProLiant DL325 Gen10 Plus v2 Power Supplies
Genuine HPE Flex Slot power supplies for the HPE ProLiant DL325 Gen10 Plus v2, new and refurbished. The chassis takes one or two hot-plug PSUs — two matching supplies give 1+1 redundancy with tool-less replacement, and HPE does not support mixing power supplies in one server.
DL325 Gen10 Plus v2 Power Supply Specifications
- Family: HPE Flex Slot hot-plug, tool-less modules — one or two per chassis
- AC options: 500W Platinum and 800W Platinum at 94% efficiency, 800W Titanium at 96%, 1000W Titanium, and 1600W Platinum at 94%
- DC and universal options: an 800W -48VDC unit and an 800W Universal high-voltage AC/DC unit taking 277VAC or 380VDC input
- Input: rated line voltage of 100–120 VAC or 200–240 VAC per supply
- Voltage rules: the 800W Titanium and the 1600W Platinum are flagged 200–240VAC only; the 500W and 800W Platinum units deliver full rated output at 100 VAC
- In the box: each option kit contains the specified power supply and a PDU IEC cable
Match before you add. All power supplies in a DL325 Gen10 Plus v2 should match — mixing them is not supported — so add redundancy using the exact part number already installed. Check the feed too: the 800W Titanium and the 1600W Platinum are 200–240VAC only.
How many power supplies does the DL325 Gen10 Plus v2 need?
| Build | PSUs | Typical choice | Notes |
|---|---|---|---|
| Entry: 16-core 155W CPU, 8SFF SAS/SATA | 2 (1+1 redundant) | 500W Platinum | The wattage HPE ships in the entry and base models |
| General purpose: 24-core 200W CPU, 10SFF | 2 (1+1 redundant) | 800W Platinum or Titanium | Titanium is 96% efficient but high-line only |
| Loaded: 280W CPU, full NVMe, 100GbE | 2 (1+1 redundant) | 1000W Titanium or 1600W Platinum | The 1600W unit supports high line voltage only |
| DC plant or 277VAC feed | 2 (1+1 redundant) | 800W -48VDC or 800W Universal | Match the unit to the facility feed, not the load |
Production systems should run two supplies — hot-plug Flex Slot modules then let you replace a failed unit without downtime. Right-size rather than over-size: HPE recommends running the Power Advisor against your exact configuration before choosing a wattage.
Choosing the Right DL325 Gen10 Plus v2 Power Supply
- Never mix wattages or models — all power supplies in a server should match, so add redundancy using the exact part number already installed.
- Check your feed first: the 800W Titanium and the 1600W Platinum require 200–240VAC, while the 500W and 800W Platinum units run on either 100–120 or 200–240 VAC.
- Efficiency has a number: Platinum units are rated up to 94% and Titanium up to 96%, which is what makes the 800W Titanium and 1000W Titanium the efficiency picks in this lineup.
- Refurbished PSUs are a low-risk buy — sealed, tested modules and a common way to bring a single-supply server up to 1+1 redundancy affordably.
Complete Your DL325 Gen10 Plus v2 Build
Pair redundant power with the rest of the platform: DL325 Gen10 Plus v2 memory, drives, controllers, adapters, processors, or the full DL325 Gen10 Plus v2 parts page. Neighboring generations: DL325 Gen10 Plus power supplies, DL325 Gen11 power supplies, and the two-socket DL385 Gen10 Plus v2 power supplies. Catalog-wide: HPE parts by server model.
DL325 Gen10 Plus v2 Power Supplies FAQ
What power supplies does the HPE ProLiant DL325 Gen10 Plus v2 use?
HPE Flex Slot hot-plug supplies: 500W Platinum, 800W Platinum, 800W Titanium, 1000W Titanium, and 1600W Platinum, plus an 800W -48VDC unit and an 800W Universal high-voltage AC/DC unit. The server takes one or two.
Can I mix different power supplies in the DL325 Gen10 Plus v2?
No. The QuickSpecs states that all power supplies in a server should match and that mixing power supplies is not supported. When adding redundancy, order the exact part number already installed.
Does the 1600W power supply work on 110V power?
No. The 1600W Flex Slot Platinum supply supports high line voltage only, at 200-240VAC. On a 100-120VAC feed, use the 500W or 800W Platinum options instead.
Can I hot-swap a failed DL325 Gen10 Plus v2 power supply?
Yes, provided two supplies are installed for 1+1 redundancy. Flex Slot supplies are hot plug and tool-less, so you can pull the failed module and insert the replacement without shutting the server down.
What is the difference between Platinum and Titanium Flex Slot supplies?
Efficiency rating. Platinum units are rated up to 94% efficiency and Titanium up to 96%. The 800W Titanium option carries a 200-240VAC input restriction that the 800W Platinum does not.
How do I work out which wattage my DL325 Gen10 Plus v2 needs?
HPE recommends running the Power Advisor tool against your exact configuration before selecting a supply. Processor wattage is the biggest single variable here, ranging from 120W up to 280W.