HPE ProLiant DL365 Gen10 Plus Power Supplies
Genuine HPE Flex Slot power supplies for the HPE ProLiant DL365 Gen10 Plus, new and refurbished. Flex Slot supplies are hot-plug and tool-less, and the platform's rule is short: all power supplies in a server should match, and mixing power supplies is not supported.
DL365 Gen10 Plus Power Supply Specifications
- Family: HPE Flex Slot hot-plug, tool-less modules; the rear view shows hot-plug power supply bays 1 and 2
- Quantity, as printed: Step 2c says to select one or two power supplies from the list; the notes block in that same section says to select one or more
- AC options: 500W Platinum, 800W Platinum, 800W Titanium, 800W universal high-voltage AC/DC, 1000W Titanium, and 1600W Platinum
- DC options: 800W -48VDC and 1600W -48VDC, the latter paired with the 1600W -48VDC Power Cable Lug Kit
- Efficiency: Flex Slot Platinum up to 94%, Titanium up to 96%, -48VDC up to 94%, universal up to 94% with both 277VAC and 380VDC input
- Line voltage: rated line voltage per supply is 100 to 120 VAC and 200 to 240 VAC; the 1000W, 1600W, and 2200W supplies are stated to support high line voltage only
Read the 1800W–2200W kit's own note before you size it. That Flex Slot Titanium supply is orderable for this server, and its note states Gen10 Plus output is capped at 1600W maximum, with greater than 1600W only feasible on Gen11 systems. Either way, all power supplies in a server should match.
Which power supply does the DL365 Gen10 Plus need?
| Power supply | Grade | Efficiency | Input as stated |
|---|---|---|---|
| 500W Flex Slot | Platinum | up to 94% | No high-line restriction stated |
| 800W Flex Slot | Platinum | up to 94% | No high-line restriction stated |
| 800W Flex Slot | Titanium | up to 96% | 200–240VAC only |
| 1000W Flex Slot | Titanium | up to 96% | 200–240VAC only |
| 1600W Flex Slot | Platinum | up to 94% | 200–240VAC only |
One entry needs reading twice. An 1800W–2200W Flex Slot Titanium kit is orderable for this server, and its own note states Gen10 Plus output is capped at 1600W maximum, with greater than 1600W only feasible on Gen11 systems.
Choosing the Right DL365 Gen10 Plus Power Supply
- Never mix wattages or models. The QuickSpecs state that mixing of 2 different power supplies is not allowed, and that all power supplies in a server should match.
- Check your feed before you size up. The 1000W, 1600W, and 2200W supplies support high line voltage only, stated as 200VAC to 240VAC.
- Buy the lug kit with the DC supply. The 1600W -48VDC Power Cable Lug Kit is the mate for the 1600W -48VDC supply, and only one lug kit is selected per supply.
- Refurbished PSUs are a low-risk buy — sealed, tested modules, and the usual way to add a second matching supply for redundancy at lower cost.
Complete Your DL365 Gen10 Plus Build
Pair redundant power with the rest of the platform: DL365 Gen10 Plus memory, drives, storage controllers, networking adapters, processors, or the full DL365 Gen10 Plus parts page. Neighbors: DL365 Gen11 power supplies and DL385 Gen10 Plus v2 power supplies. Catalog-wide: HPE parts by server model.
DL365 Gen10 Plus Power Supplies FAQ
What power supplies does the HPE ProLiant DL365 Gen10 Plus use?
HPE Flex Slot hot-plug supplies. The option list covers 500W Platinum, 800W Platinum, 800W Titanium, 800W universal high-voltage AC/DC, 800W -48VDC, 1000W Titanium, 1600W Platinum, 1600W -48VDC, and an 1800W-2200W Titanium kit.
How many power supplies does a DL365 Gen10 Plus take?
The document states it two ways. Step 2c says to select one or two power supplies from below; the notes block in that same section says to select one or more. The rear view shows hot-plug power supply bays 1 and 2.
Can I mix different power supplies in the DL365 Gen10 Plus?
No. The QuickSpecs state that mixing of 2 different power supplies is not allowed, and that all power supplies in a server should match. When adding a second supply, buy the exact part number already installed.
Does the 1600W power supply work on 110V power?
No. The QuickSpecs state that the 1000W, 1600W, and 2200W power supplies only support high line voltage, 200VAC to 240VAC. Rated line voltage per supply is listed as 100 to 120 VAC and 200 to 240 VAC.
Why is an 1800W-2200W power supply listed for this server?
It is an orderable option, and its own note states that Gen10 Plus and v2 output is capped at 1600W maximum, with greater than 1600W only feasible on Gen11 systems. Size the build against that note.
Can I hot-swap a failed DL365 Gen10 Plus power supply?
Flex Slot supplies are hot-plug and tool-less, and the internal view describes the server's supplies as hot-plug redundant. With two matching supplies installed, a failed module is replaced in place.