HPE ProLiant DL360 Gen10 Plus Power Supplies
Genuine HPE Flex Slot power supplies for the HPE ProLiant DL360 Gen10 Plus, new and refurbished. The platform runs one or two hot-plug PSUs — two matching supplies give full 1+1 redundancy with tool-less replacement.
DL360 Gen10 Plus Power Supply Specifications
- Family: HPE Flex Slot hot-plug, tool-less modules
- Options: 500W Platinum, 800W Platinum, 800W Titanium, 1000W Titanium, and 1600W Platinum
- Quantity: one or two; two matching PSUs provide 1+1 redundancy
- Rules: both installed PSUs must match; the 1600W unit requires high-line 200–240VAC
Match before you add. Both power supplies in a DL360 Gen10 Plus must be the identical model — and the 1600W unit requires 200–240VAC high-line power.
How many power supplies does the DL360 Gen10 Plus need?
| Configuration | PSUs | Typical choice |
|---|---|---|
| Light build: 1 CPU, few drives | 2 (1+1 redundant) | 500W |
| General-purpose 2P build | 2 (1+1 redundant) | 800W or 1000W |
| Loaded: 40-core CPUs, NVMe | 2 (1+1 redundant) | 1600W |
Production systems should run two supplies — hot-plug modules then let you replace a failed unit without downtime. Size the exact build with HPE Power Advisor.
Choosing the Right DL360 Gen10 Plus Power Supply
- Never mix wattages or models — both PSUs in the chassis must be identical.
- Check your feed: the 1600W unit requires 200–240VAC high-line power.
- Refurbished PSUs are a low-risk buy — sealed, tested modules and a popular way to add redundancy affordably.
Complete Your DL360 Gen10 Plus Build
Pair redundant power with the rest of the platform: DL360 Gen10 Plus memory, drives, storage controllers, networking adapters, processors, or the full DL360 Gen10 Plus parts page. Neighboring generations: DL360 Gen10 power supplies and DL360 Gen11 power supplies. Catalog-wide: HPE parts by server model.
DL360 Gen10 Plus Power Supplies FAQ
What power supplies does the HPE ProLiant DL360 Gen10 Plus use?
HPE Flex Slot hot-plug PSUs: 500W Platinum, 800W Platinum, 800W Titanium, 1000W Titanium, and 1600W Platinum. The server runs one or two, always matching.
Can I mix different power supplies in the DL360 Gen10 Plus?
No - both units must be the same model and wattage. When adding redundancy, buy the exact part number already installed.
Does the 1600W power supply work on 110V power?
No - the 1600W unit requires high-line 200-240VAC. On low-line power, use the 500W-1000W options.
Can I hot-swap a failed DL360 Gen10 Plus power supply?
Yes, provided two supplies are installed (1+1 redundancy) - pull the failed module and insert the replacement without shutting down.
Will DL360 Gen10 power supplies fit the Gen10 Plus?
The Flex Slot form factor is shared across generations, but stick to the part numbers listed in the Gen10 Plus QuickSpecs - supported wattage lineups differ by platform and configuration.
✅ Looking for a specific DL360 Gen10 Plus power supply? Browse our full selection below.