HPE ProLiant ML350p Gen8 Power Supplies

HPE ProLiant ML350p Gen8 Power Supplies

HPE ProLiant ML350p Gen8 Power Supplies

Genuine HPE Common Slot hot-plug power supplies for the HPE ProLiant ML350p Gen8, new and refurbished. One rule governs every order on this page: HPE does not support mixing power supplies in the same server — all supplies inside one chassis must be exactly the same model, and Gold, Platinum and Platinum Plus units cannot be combined.

ML350p Gen8 Power Supply Specifications

  • Format: HPE Common Slot (CS) hot-plug supplies, a form factor shared across several ProLiant generations
  • Outputs stocked: 460W, 750W and 1200W in Platinum Plus, 460W and 750W in Gold, and a 750W −48VDC unit
  • Efficiency: Platinum Plus units deliver 94% efficiency and support Intelligent Power Discovery; Gold units are rated up to 92%
  • Redundancy: optional 1+1 through power supply option kits, with hot-plug replacement of the failed unit
  • Input: 100 to 240 VAC at 50 to 60 Hz per supply, 7.1 Amps at 120VAC down to 3.5 Amps at 240VAC
  • Heat output: 1773 BTU per hour on the 460W unit at 120VAC, 2892 on the 750W and 3530 on the 1200W — it matters when a tower shares a room
  • Cooling: three hot-plug non-redundant fans on entry and base models; the Hot Plug Redundant Fan Kit adds a fourth fan plus PCIe baffles and louvers, which performance models carry from the factory

Mixing power supplies is not supported. HPE requires every supply inside one server to be exactly the same model, and Gold, Platinum and Platinum Plus units cannot be combined — two 750W supplies are still a mismatch if the grades differ. Read the label on the installed unit before ordering the second.

Which Wattage and Grade Does Your Tower Need?

OutputGrades stockedHeat at 120VACSuits
460WPlatinum Plus, Gold1773 BTU/hrOne processor, one drive cage, no accelerators
750WPlatinum Plus, Gold, −48VDC2892 BTU/hrTwo processors with a populated cage — the common choice
1200WPlatinum Plus3530 BTU/hrTwo high-wattage processors, three cages, graphics cards

Oversizing costs efficiency as well as money: a supply running far below its rated load sits away from its best efficiency point, and in a tower that heat lands in the room the server stands in. HPE publishes a Power Advisor for sizing a configuration; the shortcut on a server of this age is to match what is fitted, unless it has gained processors, cages or graphics cards since.

Choosing the Right ML350p Gen8 Power Supply

  • Read the label on the installed unit first. HPE requires every supply in one server to be the same model, so the existing supply is the specification, not a starting point.
  • Platinum Plus and Gold do not mix. Two 750W units are still a mismatch if the grades differ, and mismatched supplies produce errors rather than running at the lower rating.
  • Redundancy means two identical units. A 1+1 configuration is a matched pair; one supply in a two-bay chassis is not redundant, whatever its rating.
  • −48VDC is a different world. That unit belongs on DC rectifier feeds and ships with no power cable at all, using a terminal block so the cord can be made up on site.
  • If the noise is the problem, look at the fans. Entry and base models run three non-redundant fans; the redundant fan kit adds the fourth plus baffles and louvers, as the performance model ships.

Complete Your ML350p Gen8 Build

Power draw follows the processors, cage count and any graphics cards — see ML350p Gen8 processors and drives before sizing a supply. Also available: memory, storage controllers and networking adapters, or the full ML350p Gen8 parts listing. Background reading: fixing excessive fan noise. Other models: HPE parts by server model.

ML350p Gen8 Power Supplies FAQ

Can I mix power supplies in an ML350p Gen8?
No. HPE states that all power supplies inside a server must be exactly the same model, and that mixing Gold, Platinum and Platinum Plus certified supplies is not supported. Mismatched units produce errors rather than running at the lower rating.

What wattage power supply does an ML350p Gen8 need?
It depends on the configuration. 460W suits a lightly loaded single-processor tower, 750W covers most two-processor builds with a populated cage, and 1200W is for heavily populated machines.

What is the difference between Platinum Plus and Gold?
They are efficiency grades. Platinum Plus units are rated at 94% and support Intelligent Power Discovery; Gold units are rated up to 92%. The two grades cannot be mixed in one chassis.

Are ML350p Gen8 power supplies hot-plug?
Yes. The Common Slot supplies are hot-plug, and in a 1+1 redundant pair one can be replaced while the server keeps running.

What is the minus 48VDC power supply for?
Racks and rooms fed by DC rectifiers rather than an AC supply. It ships with no power cable and uses a terminal block, so it is not a drop-in replacement for an AC unit.

How many fans does an ML350p Gen8 have?
Three hot-plug fans on entry and base models and four on performance models. The Hot Plug Redundant Fan Kit brings an entry or base machine to four fans, with the PCIe baffles and louvers that fan redundancy requires.

✅ Looking for a specific ML350p Gen8 power supply? Browse our full selection below.

Parts Finder Narrow to your model…
Compare Selected