2 Port SATA RAID Cable Kit for ML150G2 NOTE: 2 Port SATA RAID Cable Kit (P/N: 379093-B21) required when using the HP 6-Port SATA RAID controller (P/N: 372953-B21) and supporting more than 4 SATA hard disk drives.
NOTE: SAS hard drives require a SAS HBA or Smart Array Controller.
NOTE: Only hot plug drives are supported on the ML150 G3; these hot plug drives, when installed on Non-hot plug models, will not have hot plug functionality.
NOTE: The purchase of SAS HBA or array controller is required.
HP SAS/SATA 4 in 1 to 4 in Cable NOTE: This cable is required when adding either the HP 8 Internal Port SAS HBA with RAID or the HP Smart Array E200 on a hot-plug SATA model or SC44GE HBA.
HP Internal SAS/SATA 4-Port Cable NOTE: This cable is required when adding either the HP 8 Internal Port SAS HBA with RAID or the HP Smart Array E200 on a non hot-plug SATA model
NOTE: Hot plug SATA servers come with a hot plug backplane, making them hot plug ready. For full hot plug capability on the hot plug SATA models, a hot plug controller (347786-B21) must also be purchased
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: The previous generation of 1.5G SATA Non-Hot Plug hard drives are supported. These drives can be purchased as an option, however, are no longer configurable.
HP Internal SAS/SATA 4-Port Cable NOTE: This cable is required when adding either the HP SC44Ge HBA (P/N 416096-B21) or the HP Smart Array E200 (P/N 411508-B21) on Non-Hot Plug SATA server models.
HP SC44Ge SAS PCI-E Host Bus Adapter NOTE: When using the SC44Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. Transfer rate: 1.5 Gb/s SATA, 3 Gb/s SAS.
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator.
NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details.
NOTE: Mixing SAS and SATA hard drives is allowed. However, only SAS hard drives will be used for RAID setting.
NOTE: The previous generations of 1.5G SATA non-hot plug hard drives are supported. These drives can be purchased as an option. However, they can no longer be configurable.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs
Power Supplies
750W CS HE Gold Hot Plug Power Supply NOTE: 750W RPS requires a Redundant Power Supply Enablement Kit 5U G6 (P/N 508544-B21). Two (1) 750W PSUs and one (1) RPS enablement kit are required to achieve redundancy.
Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. NOTE: Supported on HP Smart Array P212 Controller, HP Smart Array P410 Controller, and HP Smart Array P411 Controller only.
HP NHP Internal SAS/SATA 4 Port Cable Kit NOTE: NHP Internal SAS/SATA 4 Port Cable (487734-B21) is required when adding Smart Array P410 Controller on Non-Hot Plug SATA/SAS server models.