NOTE: If selecting more than 4 hard drives a Smart Array controller and two SAS/SATA cables (P/N 453255-B21) are required.
Storage Controllers
SAS Controllers
HP 8 Internal Port SAS HBA with RAID NOTE: For use with Hot Plug SAS/SATA models. Required only when upgrading from a non-hot plug to a hot plug model. NOTE: The selection HP 8 Internal Port SAS HBA with RAID requires the purchase of the PCI-X Riser Option kit (P/N 409347-B21)
HP ProLiant DL180 PCI/X Riser Kit NOTE: This option kit replaces the three internal expansion slots listed in step 1 base configuration. NOTE: Optional PCI-X option kit includes: Slot 1: full-length/full-height PCI-X 100; Slot 2: Full length/Full-height PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.
NOTE: Optical drives can only be installed on 8 bay hard drive models.
Hard Drives
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
High Efficiency HP 1200W 12V Hot Plug AC Power Supply NOTE: Redundant Power Supply configuration for 1200W power supply requires both power supplies to be 1200W. The 1200W and 750W power supplies cannot be mixed.
HP Smart Array E500/256MB Controller NOTE: When ordering a Smart Array E500 Controller with BBWC the addition of the HP SA-P400 and SA-E500 24" Battery Cable Kit (417836-B21) is required.
HP SA-P400 and SA-E500 24 In Battery Cable Kit NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the server if a Smart Array P400 or Smart Array E500 is integrated outside of the factory. For all solutions, please refer to the server QuickSpecs and User's Manual for detailed installation instructions.
HP Smart Array P400/512MB Controller with BBWC NOTE: When ordering a Smart Array P400 Controller with BBWC the addition of the HP SA-P400 and SA-E500 24" Battery (417836-B21) is required.
HP SA-P400 and SA-E500 24 In Battery Cable Kit NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the server if a Smart Array P400 or Smart Array E500 is integrated outside of the factory. For all solutions, please refer to the server QuickSpecs and User's Manual for detailed installation instructions.
Internal SAS/SATA Cable NOTE: If selecting more than 4 hard drives or if using SAS hard drives a Smart Array controller is required and two SAS/SATA cables. NOTE: The addition of a Smart Array Controller requires the addition of a SAS/SATA Multi-lane cable.
HP SC44Ge Host Bus Adapter NOTE: When using the SC44Ge with SATA Hard Drives, 1.5G SATA Hard Drives are required. Transfer rate: 1.5 Gb/s SATA, 3 Gb/s SAS.
HP DL180 G6 3PCI-E x8, Full Height Kit NOTE: This option provides two x8 full-length/full-height slots as well as an additional x8 (x4 electrically) slot. This allows the DL180G6 to have a maximum of four (4) slots.
HP PCI-X Full Riser DL180 G6 Kit NOTE: This option kit replaces the three internal expansion slots listed in step 1 base configuration. NOTE: Optional PCI-X option kit includes: Slot 1: full-length/full-height PCI-X 100; Slot 2: Full length/Full-height PCI-X 100. PCI-X slots are 64 bits; 133 MHz capable if only one PCI-X card is installed in the server.
HP 2U G6 8HDD LFF DL18X KIT NOTE: Upgrading to 8 Hot Plug SATA/SAS hard drives requires the addition of a storage controller (Smart Array P410/256MB recommended), two Internal ATA/SAS cables, (mini-SAS cable (496013-B21).
HP DL180G6 Rear 2LFF Kit NOTE: Supports 12 hard drive server models only. Hard Drives not included. NOTE: This option replaces the 2 Full Length, Full Height x8 PCIe slots.
NOTE: HT indicates that the processor model supports Intel Hyper-Threading Technology.
NOTE: Turbo indicates the maximum potential frequency increment when using Intel Turbo Boost Technology, with 4, 3, 2, and 1 cores active.
NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed.
NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage.
NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration rules and guidelines, please use the Online DDR3 Memory Configuration Tool: http://www.hp.com/go/ddr3memory-configurator
NOTE: Optical drives can only be installed on 8 bay hard drive models.
Hard Drives
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: If selecting more than 4 hard drives or if using SAS hard drives, a Smart Array controller and two SAS/SATA cables (P/N 464830-B21) are required.
HP Smart Array P800/512 BBWC Controller NOTE: The HP Smart Array P800 controller provides support for external storage on the DL180G6 server. Local storage is supported on the DL180 using either the P212 or P410 controllers.
Battery Kit upgrade NOTE: To enable BBWC on the 256MB cache. NOTE: Supported on HP Smart Array P212 Controller, HP Smart Array P410 Controller, and HP Smart Array P411 Controller only.