NOTE: Processors 2374 HE and above use PC2-6400 memory except for 8GB DIMMs which remain PC2-5300 (408855-B21 and 495605-B21). PC2-5300 memory (except for kits 408855-B21 and 495605-B21) can only be used with processor models 2360 SE and below.
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details.
Serial-ATA (SATA) Non-Hot Plug Hard Drives (Non-Hot Plug Models Only)
Hot Plug HDD Backplane 1U 2S Kit NOTE: Installation of the Hot Plug Backplane 1U 2S Kit (445985-B21) is required if ordering third or fourth Hard Drives for Hot Plug models only.
HP Smart Array E500/256MB Controller NOTE: Standard RAID 0,1, 1+0. NOTE: Customers can only order one Smart Array E500/256MB Controller and one Battery-backed write cache upgrade (P/N 383280-B21) for the HP ProLiant DL165 G5 server based on battery space.
HP Smart Array P400/256MB Controller NOTE: Customers can only order one Smart Array P400/256MB Controller and one Battery-backed write cache upgrade (P/N 383280-B21) for the HP ProLiant DL165 G5 server based on battery space.
HP Smart Array P400/512MB BBWC Controller NOTE: Customers can only order one Smart Array P400/512MB BBWC Controllers for the HP ProLiant DL165 G5 server based on battery space.
Battery-backed write cache upgrade NOTE: Contains battery only. For Smart Array P400 Controller. NOTE: RAID 5 support. When installing a battery-backed write cache module, the HP Smart Array E500 must be installed in the full-length PCI slot.
HP 8 Internal Port SAS HBA with RAID NOTE: For use with Hot Plug SAS/SATA models. NOTE: The selection HP 8 Internal Port SAS HBA with RAID requires the purchase of the LowProfile PCI-X Riser Option kit (P/N 452698-B21).
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
Serial-ATA (SATA) Non-Hot Plug Hard Drives (Non-Hot Plug Models Only)
HP Smart Array P400/256MB Controller NOTE: Customers can only order one Smart Array P400/256MB Controller and one Battery-backed write cache upgrade (P/N 383280-B21) for the HP ProLiant DL165 G5 server based on battery space.
HP Smart Array P400/512MB BBWC Controller NOTE: Customers can only order one Smart Array P400/512MB BBWC Controllers for the HP ProLiant DL165 G5p server based on battery space.
HP SA-P400 and SA-E500 24 In Battery Cable Kit NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the following servers if a Smart Array E500 is integrated outside of the factory. For all solutions, please refer to the HP ProLiant QuickSpecs and User's Manual for detailed installation instruction.
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.
NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services.
NOTE: The components of a storage subsystem (e.g. the drive, the HBA/controller, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.
NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs
Cooling Options
HP DL165G7 Redundant Fan OPT KIT NOTE: Redundant Fan Option Kit ONLY required for fan redundancy in single processor configurations. Two processor configurations offer N+1 fan redundancy as standard.
NOTE: To utilize the internal only slot, the HP Smart Array P410 Controller must be selected. The selection of the HP Smart Array P212 Controller for internal and external connectivity, will require the use of the Full Length Full Height PCI-E x16 slot.
NOTE: With the HP Smart Array P410 Controller, the addition of the battery backed cache upgrade enables BBWC, RAID 5, 5+0, array expansion, logical drive extension, RAID migration, and stripe size migration. In order to upgrade to RAID 6, at least 256MB Cache and a Battery is required in addition to the HP Smart Array Advanced Pack license (P/N 516471-B21).